Overview

ASD310 provides mimic diagram, HV live display, intelligent temp/humidity control (two heating, one fan), voice prompts, human body induction, trip/close supervision and voltage measurement, breaker counter, and RS485 Modbus for 3-35kV switchgear. It offers comprehensive status and safety monitoring without power measurement or wireless temperature. Ideal for standard switchgear applications.

Highlight

Reliable Power & Communication

  • AC/DC wide-range power supply
  • Low power consumption <6VA
  • RS485 Modbus-RTU communication
  • Power-off alarm output
  • Industrial-grade components

HV Live Display & Phase Check

  • 3-phase live LED indication
  • Built-in self-test button
  • External phase matching support
  • 1 electromagnetic lock output
  • Unlock when all phases dead

Smart Temp./Humidity Control

  • 1 external sensor (4m cable)
  • 2 heating + 1 fan outputs
  • Forced heating mode
  • Heating circuit fault alarm
  • Adjustable thresholds

Enhanced Safety & Monitoring

  • Voice error-prevention prompts
  • Human body induction (auto backlight)
  • Trip/close circuit supervision
  • Trip/close voltage measurement
  • Breaker operation counter

Function

FunctionDescription
Mimic DiagramDynamic LED display showing breaker, disconnector (trolley), earthing switch, and spring status.
HV Live DisplayPhase-by-phase LED indication for live voltage; supports external phase matching via test holes.
Electromagnetic LockOne lock output, controlled by live voltage; unlocks when all phases dead.
Temperature/Humidity CtrlOne external sensor (4m cable); controls two heating outputs and one fan output based on user-set thresholds (adjustable via front panel or communication).
Heating Circuit AlarmDetects open circuit or overload of heating loads and reports alarm.
Voice Error–PreventionVoice prompts when unsafe operation is attempted (e.g., moving trolley with breaker closed). Two selectable modes.
Human Body InductionAutomatically turns on backlight and cabinet lighting when operator approaches.
Trip/Close SupervisionMonitors continuity of trip and close circuits; indicates circuit health via LEDs.
Trip/Close Voltage Meas.Measures control voltage on trip and close circuits (accuracy class 1).
Breaker Operation CounterRecords number of breaker operations; can be reset via menu.
RS485 CommunicationModbus-RTU protocol, baud rate 2400-19200, for remote monitoring and parameter setting.
Power–off AlarmRelay output closes upon auxiliary power loss.

Specification

ParameterValue
Auxiliary PowerAC 85~265V or DC 100~300V
Power Consumption≤6 VA
CommunicationRS485, Modbus-RTU, 2400-19200 bps
Temperature Measurement±1℃
Humidity Measurement±3% RH
Trip/Close Voltage Acc.Class 1
Digital Inputs8 opto-isolated (passive contacts)
Relay OutputsHeating I, Heating II, Fan, Alarm, Lock, Lighting (depending on model)
Operating Temperature-10℃ ~ +55℃
Relative Humidity≤95% (no condensation)
MTBF≥50,000 hours
Dimensions (W×H×D)238 mm × 178 mm × 83 mm
Panel Cut–out220 mm × 165 mm
MountingPanel flush mounting
WeightApprox. 1.2 kg
Front Panel ProtectionIP40

FAQ

Does ASD310 support wireless temperature measurement or power parameter measurement?

No. ASD310 does not have wireless temperature measurement nor power parameter measurement (current, voltage, etc.). For wireless temperature monitoring, please consider ASD300 or ASD320; for power measurement, please consider ASD300.

Can the temperature/humidity sensor cable be extended?

The standard cable length is 4 meters. For longer lengths, please contact us before ordering.

How to set temperature/humidity thresholds?

You can set them via the front panel keys (see manual section 2.4) or via RS485 communication.

How many voice prompt modes are available? How to switch?

Two modes: Mode 1 (prompts both breaker and earthing switch), Mode 2 (only breaker). Switch via the system setup menu.

What is the measurement range for trip/close circuit voltage?

The range is 0~6553.5V (primary side value), accuracy class 1. It measures the secondary control voltage and displays the primary value after transformation.

Summary

ASD310 delivers essential monitoring and safety functions at a competitive cost. Voice prompts, auto-lighting, and trip/close supervision prevent misoperations. Climate control protects insulation. RS485 enables remote monitoring. Reliable and easy to install, it enhances operational safety and equipment life.

Contact Us

We’d love to hear from you!

Have a project in mind? Let’s make it happen.

Customer Testimonials

What Our Clients Say

PD Monitoring

We’ve used Acrel products on several projects, and they’ve been reliable from day one. Installation was straightforward, and the support team was always quick to answer our questions.

Saudi Arabia

Mohamed Elshazly

–

Tendering Director

Power Monitoring Solution

We were looking for a cost-effective metering solution, and Acrel was a great fit. The products work well, communication is stable, and delivery was on schedule.

United Arab Emirates

Asad Janjua

–

Electrical Engineer

Temperature Monitoring

The wireless temperature monitoring system has been running smoothly since commissioning. It helps us identify potential issues early and reduces the need for routine inspections.

Saudi Arabia

Abbas Matar

–

Project Manager

Long-Term Partnership

We’ve been working with Acrel for several years now. The products are dependable, reasonably priced, and the overall experience has always been positive.

Philippines

Arnold Bagabaldo

–

CEO

Technical Support

What we appreciated most was the technical support. The Acrel team helped us choose the right products and stayed involved until the project was completed.

Canada

David Dudley

–

System Integration Manager

SCADA Integration

The products integrated easily with our existing SCADA platform. Everything worked as expected, and commissioning was completed without any major issues.

Russia

Alexey Petrov

–

Sales manager