Overview

ADL200N is a single-phase DIN-rail energy meter with external split-core CTs.
It measures voltage, current, power, and bi-directional energy with Class B accuracy and 50ms fast response.
Ideal for residential PV, small ESS, and load monitoring.

Highlight

Multi-Model Options

  • 1Φ CT: 80A, 120A, 200A, 300A
  • Single-phase only
  • DIN-rail 1-module
  • External split-core CTs

Fast Response

  • 50ms data refresh
  • High-speed registers
  • Real-time monitoring
  • Anti-backfeed control

High Accuracy

  • Class B active energy
  • ±0.5% V, I accuracy
  • Bi-directional metering
  • 45-65Hz frequency

Standard Outputs

  • RS485 Modbus RTU
  • Pulse output LED
  • 1-247 address
  • 1200-38400 baud

Function

MeasurementMeteringExtended Functions
Voltage (U)Total Active EnergyRS485 Communication with Modbus-RTU
Current (I)Forward Active EnergyField-Programmable Parameters (CT Ratio, Comm. Address, etc.)
Active Power (P)Reverse Active EnergyActive Pulse Output (LED Indication)
Reactive Power (Q)Forward Reactive EnergyHigh/Low-Speed Dual Register Sets for Optimized Data Reading
Apparent Power (S)Reverse Reactive EnergyPassword Protection Against Unauthorized Changes
Power Factor (PF)—Backlight Control
Frequency (F)——

Specification

ItemParameter
Model SeriesADL200N-CT (Single-Phase)
Voltage Rating230V (with ±20% range)
Voltage Range184V ~ 276V
Current RatingsExternal CT Operated: Primary 80A, 120A, 200A, 300A (determined by ordered CTs)
Auxiliary PowerSelf-powered from measured line, < 0.2VA
Active Energy AccuracyClass B (per GB/T 17215.321)
Reactive Energy AccuracyClass 2
Response Speed50ms (for voltage, current, power via fast registers)
Pulse OutputActive optocoupler output, default pulse constant: 600 imp/kWh
CommunicationRS485 with Modbus-RTU protocol
Comm. ParametersAddress 1~247, baud rate 1200~38400bps programmable
DisplaySegmented LCD, programmable via buttons
Operating Temperature-25℃ ~ +55℃
Storage Temperature-40℃ ~ +70℃
Relative Humidity≤95% (non-condensing)
DimensionsMeter: approx. 18mm × 90mm × 65mm (1 module); CTs: varies by specification
MountingMeter: 35mm standard DIN rail; CTs: Clamped onto primary cables
Protection GradeIP20 (Meter body)

FAQ

What is the main difference between ADL200N-CT and ADL400N-CT?

The main difference lies in the number of phases and function complexity.

ADL200N-CT: Single-phase meter, suitable for homes, shops, and other single-phase supply scenarios. Focuses on high-precision metering and fast response for single-phase circuits, with a smaller size (1 module).

ADL400N-CT: Three-phase meter, suitable for industrial parks, commercial buildings, PV plants, and other three-phase supply scenarios. Supports configurable 3-phase 4-wire / 3-phase 3-wire.

Selection Guide: Choose based on your power supply system type. Choose ADL200N-CT for single-phase systems, and ADL400N-CT for three-phase systems.

Are the CTs for ADL200N-CT and ADL400N-CT interchangeable?

Yes, they are fully interchangeable. Both products use the exact same CT series (80A/26.7mA, 120A/40mA, 200A/66.67mA, 300A/100mA). This means if you use both single-phase and three-phase meters in a project, you can standardize CT spare parts and reduce inventory variety.

How to modify the Modbus communication address of ADL200N-CT via buttons?

The manual (pages 12-13) provides detailed steps:

In the display interface, press and hold the ▲ button for >3 seconds to enter the password screen “PASS0000”.

Briefly press ▼ to increase value, press and hold ▲ to shift cursor, enter the default password 0001.

Press and hold ▲ for >3 seconds to confirm password, enter address modification screen “addr x”.

Briefly press ▼ to modify value, press and hold ▲ to shift cursor.

After modification, press and hold ▲ for >3 seconds to enter “SAVE YES”, then press and hold ▲ again to save and exit.

Can ADL200N-CT correct reverse current direction via software?

The ADL200N-CT is designed for single-phase applications with simplicity in mind. If negative power is displayed (indicating reverse current direction), the simplest solution is to swap the two leads of the CT secondary side at the meter terminals. If remote direction identification is needed, you can determine energy flow by reading the forward/reverse energy registers.

Summary

ADL200N combines 50ms fast response, external CT flexibility, and Class B accuracy in a 1-module design. It enables reliable anti-backfeed control and real-time monitoring for residential energy systems.

Contact Us

We’d love to hear from you!

Have a project in mind? Let’s make it happen.

Customer Testimonials

What Our Clients Say

PD Monitoring

We’ve used Acrel products on several projects, and they’ve been reliable from day one. Installation was straightforward, and the support team was always quick to answer our questions.

Saudi Arabia

Mohamed Elshazly

–

Tendering Director

Power Monitoring Solution

We were looking for a cost-effective metering solution, and Acrel was a great fit. The products work well, communication is stable, and delivery was on schedule.

United Arab Emirates

Asad Janjua

–

Electrical Engineer

Temperature Monitoring

The wireless temperature monitoring system has been running smoothly since commissioning. It helps us identify potential issues early and reduces the need for routine inspections.

Saudi Arabia

Abbas Matar

–

Project Manager

Long-Term Partnership

We’ve been working with Acrel for several years now. The products are dependable, reasonably priced, and the overall experience has always been positive.

Philippines

Arnold Bagabaldo

–

CEO

Technical Support

What we appreciated most was the technical support. The Acrel team helped us choose the right products and stayed involved until the project was completed.

Canada

David Dudley

–

System Integration Manager

SCADA Integration

The products integrated easily with our existing SCADA platform. Everything worked as expected, and commissioning was completed without any major issues.

Russia

Alexey Petrov

–

Sales manager