Overview

AMC200-12DE is a DIN-rail DC multi-circuit meter for up to 12 single-phase DC channels.
It measures voltage, current, power, and energy using Hall sensors. Features 4 NTC temp sensors, humidity sensor, and RS485/4G/NB IoT.
Designed for -48V DC base stations

Highlight

Multi-Circuit DC Monitoring

  • Up to 12 single-phase DC circuits
  • Measures voltage, current, power
  • Class 0.5 voltage/current accuracy
  • Resolution: 0.01V, 0.01A, 0.01kW
  • Compact design saves panel space

Hall Sensor Interface

  • Built-in ±12V power supply
  • Supports up to 12 Hall sensors
  • Input: DC 5V from Hall sensors
  • Easy connection via terminals
  • No external power supply needed

Integrated I/O & Environment

  • 2 active + 4 passive DI
  • 2 relay outputs (250V/3A)
  • 4 NTC temperature sensors
  • 1 Temp.& Humi. sensor
  • Multiple alarm functions

Flexible Communication

  • RS485 Modbus-RTU
  • Optional 4G/NB-IoT
  • Baud rate 1200-9600
  • YD/T 1363 protocol
  • Remote monitoring ready

Function

FunctionDescription
Multi-Circuit DC MeasurementMeasures DC voltage, current, power, and energy for up to 12 single-phase circuits. Voltage range: DC -48V (nominal). Current input via Hall sensors with 5V output. Accuracy: voltage/current Class 0.5, power Class 1.0. Resolution: 0.01V, 0.01A, 0.01kW, 0.01kWh.
Digital Inputs6 channels: 2 active wet contact inputs (AC 220V) for mains/generator status, and 4 passive dry contact inputs for breaker or equipment status monitoring.
Relay Outputs2 channels of normally open relay contacts. Contact capacity: AC 250V/3A or DC 30V/3A. Supports remote control and alarm output modes.
Temperature & Humidity Monitoring4 NTC temperature sensors, range -20~100℃ (±2℃). One温湿度 sensor measures ambient temperature (-20~100℃, ±2℃) and humidity (20-90%RH, ±5%RH).
Hall Sensor Power SupplyProvides ±12V DC output to power up to 12 Hall current sensors. Eliminates need for external power supplies for sensors.
Mains MonitoringOne channel AC input detection (DC 0-5V) for monitoring mains power status. Configurable alarm thresholds.
Data StorageHistorical data storage: 60-minute interval (records), daily records, meter reading day records. Alarm history stores up to 500 events.
CommunicationRS485 interface with Modbus-RTU or YD/T 1363 (China Tower) protocol. Optional 4G or NB-IoT wireless communication for remote monitoring applications.
Alarm FunctionSupports DC over-voltage, under-voltage, primary power failure, module failure, AC input outage, and DI linkage alarms. Configurable thresholds and delays.

Specification

ParameterValue
Power SupplyDC 40~60V (nominal -48V), ≤2W (without Hall sensor load)
Voltage Input1 channel DC -48V (nominal); Overload: 1.2× rated (continuous), 2× rated/1s
Current Input12 channels via Hall sensors (5V output); Overload: 1.2× rated (continuous), 10× rated/1s
Measurement AccuracyVoltage/Current: Class 0.5; Power: Class 1.0
ResolutionVoltage: 0.01V; Current: 0.01A; Power: 0.01kW; Energy: 0.01kWh
Digital Inputs2 active (AC 220V) + 4 passive (dry contact)
Relay Outputs2 channels, NO contact; AC 250V/3A, DC 30V/3A
NTC TemperatureRange: -20~100℃, Accuracy: ±2℃
Temp.& Humi. SensorTemp: -20~100℃ (±2℃); Humidity: 20-90%RH (±5%RH)
Hall Sensor Power±12V DC output, capable of powering up to 12 Hall sensors
Mains Monitoring1 channel DC 0-5V input for AC mains detection
CommunicationRS485, Modbus-RTU or YD/T 1363; Optional 4G/NB-IoT
Baud Rate1200, 2400, 4800, 9600
Data Storage IntervalDefault 60 minutes (configurable)
Operating Temperature-20℃~+60℃
Storage Temperature-40℃~+70℃
Relative Humidity≤98% (non-condensing)
Altitude≤4000m
Insulation Resistance≥40MΩ
Dimensions (W×H×D)Refer to drawing (approx. 120×120×80 mm)
MountingDIN rail or screw mounting
WeightApprox. 0.8 kg

FAQ

How many DC circuits can the AMC200-12DE monitor?

It can monitor up to 12 single-phase DC circuits simultaneously.

What type of current sensors are required?

It requires Hall effect current sensors with 5V output, such as AHKC series. The device provides ±12V power for the sensors.

Can it monitor both DC and AC inputs?

Yes, it has one dedicated channel for AC mains monitoring (0-5V input) to detect AC power status.

What communication protocols are supported?

Modbus-RTU and YD/T 1363 (China Tower protocol) via RS485. Optional 4G or NB-IoT modules are available.

How is the device powered?

It is powered by DC 40-60V, typically from the -48V DC bus in telecom sites.

Does it store historical data?

Yes, it stores historical data at configurable intervals (default 60 minutes), daily records, meter reading day records, and up to 500 alarm events.

What alarms are available?

DC over-voltage, under-voltage, primary power failure, module failure, AC input outage, and DI alarms. Thresholds are configurable.

Summary

AMC200-12DE Enables high-density DC monitoring with 12 channels in one unit. Provides ±12V output for Hall sensors and supports wireless data transmission, optimizing space and maintenance for telecom power systems.

Contact Us

We’d love to hear from you!

Have a project in mind? Let’s make it happen.

Customer Testimonials

What Our Clients Say

PD Monitoring

We’ve used Acrel products on several projects, and they’ve been reliable from day one. Installation was straightforward, and the support team was always quick to answer our questions.

Saudi Arabia

Mohamed Elshazly

–

Tendering Director

Power Monitoring Solution

We were looking for a cost-effective metering solution, and Acrel was a great fit. The products work well, communication is stable, and delivery was on schedule.

United Arab Emirates

Asad Janjua

–

Electrical Engineer

Temperature Monitoring

The wireless temperature monitoring system has been running smoothly since commissioning. It helps us identify potential issues early and reduces the need for routine inspections.

Saudi Arabia

Abbas Matar

–

Project Manager

Long-Term Partnership

We’ve been working with Acrel for several years now. The products are dependable, reasonably priced, and the overall experience has always been positive.

Philippines

Arnold Bagabaldo

–

CEO

Technical Support

What we appreciated most was the technical support. The Acrel team helped us choose the right products and stayed involved until the project was completed.

Canada

David Dudley

–

System Integration Manager

SCADA Integration

The products integrated easily with our existing SCADA platform. Everything worked as expected, and commissioning was completed without any major issues.

Russia

Alexey Petrov

–

Sales manager